Flow curve generator
Engineering data. Publication-ready output.
Shading, engineering notes, and the watermark travel with your export.
FLOW & PUMP CALCULATOR TOOLALL IN ONE CALCULATOR
Compare pump heads, total flow, pressure, gearbox and motor requirements.
Gearbox choices must have a matching source flow curve.
Pump data checked against the supplied handover and current CheckPoint performance documents, 8 October 2026. The supplied legacy SLA 3/16-inch configuration is available for internal review and is identified on its result card. Capacity is linearly interpolated within each published curve; it is never extrapolated.
Results show possible pump matches, conditional on the listed supply or speed/reducer configuration and head-material rating. Selection assumes continuous duty where a limit is published. SLA sizing minimum is the selected curve peak divided by 40. Minimum flow uses the published floor and any stated sizing convention, multiplied by the same head-count factor as flow. Head-count limits follow the supplied configuration guidance. Multi-head flows assume identical heads at the same duty and speed; drive loading needs separate confirmation unless a matching motor result is shown. No flow correction is made for viscosity, gas, chemical compatibility, relief settings, suction conditions, or application margin.
Data audit and manufacturer sourcesLoading local catalog…
MOTOR SIZING
Updated SLA charts and source-specific motor sizing.
Updated Adam charts, dated 1 June 2026. Select the complete pump arrangement and discharge pressure.
Chart basis: 1-inch stroke and the stated 5% safety factor. Motor power is taken directly from the selected chart; it is not scaled to other speeds, stroke lengths, or mixed head duties.
UPDATED SLA CHART RESULT
Your duty matches a published pressure column. The kW result is an HP conversion, not a separate IEC motor selection.
Source cell: 'HP Charts 1-2 Head(Adam)'!F26
SLA Motor Power Charts RevA 20200302BG Unlocked.xlsm. Uses the updated HP Charts 1–2, 3–4 and 5–6 Head(Adam) tabs, and only the 9:1 and 15:1 tables at 1450 or 1750 rpm.
Select the first pressure column at or above the duty. Blank cells and pressures above the chart’s row limit do not produce a motor selection. No interpolation or extrapolation is used. kW = HP × 0.7456999.
The head groups follow the worksheet names and validity notes. For two heads with different duties, the source says to use the higher motor requirement. Different simultaneous duties across larger multi-head arrangements need a separate review.
POWER CALCULATION
Calculate brake horsepower from flow or an SLA head configuration.
CALCULATED POWER
From total flow and mechanical efficiency.
At the output shaft.
API pump datasheet BHP value, as identified in the supplied workbook.
Calculated shaft power. Use Motor sizing to select the motor.
Flow method (Sheet1, B3:B14): Hydraulic hp = total flow (US gal/min) × pump differential pressure (psi) ÷ 1714. Full-pump BHP = hydraulic hp ÷ mechanical efficiency as a fraction. The workbook starts at 85% and describes 85–95% as a general assumption.
SLA method (Sheet1, B20:B34): Output rpm = motor rpm ÷ gear ratio. Rod load (lbf) = π × plunger diameter² (in) ÷ 4 × discharge pressure (psi). BHP per head = rod load × stroke (in) × output rpm ÷ 396000. Combined SLA BHP = per-head BHP × number of identical heads. The workbook identifies this combined result as the API pump datasheet BHP value. No further efficiency factor is applied to this method.
Units and comparison: Both methods use kW = hp × 0.7457. Flow and pressure selections are converted to the workbook’s US gal/min and psi before calculation. The workbook suggests the methods should agree within about 20%. Here, percentage difference = absolute difference ÷ flow-based full-pump BHP × 100. The two pressure inputs remain separate because differential pressure and discharge pressure can differ.
Source example: Reset example restores the workbook inputs. These produce different BHP results and trigger the comparison note. The workbook’s gearbox dropdown includes 15:1 and 9:1. This power calculation does not establish allowable pressure, rod load or a selected motor size.
Download source BHP workbook