CheckPoint · engineering source review

Pump data audit

Published performance sources checked on 8 October 2026. This report records the evidence, corrections and selection conventions behind the calculator data. It distinguishes current chart verification from table-only and supplied-document evidence.

78Handover models reviewed
5Additional Engineering2 curve models
14Archived MD / MDZ / S table models

Major changes identified

Family / modelAudit outcome
ATP modularSix single- and dual-head models: change 12 reducer labels from 28.88:1 to 27.55:1. All 124 stored ATP points agree with the current charts within rendering resolution. Standard ATP flow caps follow the applicable empirical curves; 3/8-inch MAWP is 3,500 PSIG.
FXA 1500 1/2-inchReplace the incorrectly scaled curves. The current chart reaches about 4.37 US gal/h at zero pressure and ends at 10,000 PSIG, rather than the handover’s 15,000-PSI endpoint. Trace all FXA motor curves individually instead of deriving secondary curves solely from ratios.
1500, 6200, 8400 & GX15Nine pneumatic models need curve, supply-label, minimum-flow or rating corrections. Key changes include 2,250 PSIG for the 1500 1-1/2-inch, 150-PSIG high supply for 6212 and 8408, 175-PSIG high supply for 8412, and the printed 8400 minimums. Individual results appear below.
FXSUpdate four minimum-flow fields, replace copied FXA footer specifications, and retain separate full-power curves and solar daily-capacity assumptions. Keep the lower 3,250 / 1,850 PSIG limits for the 3/8 / 1/2-inch models while source conflicts remain open.
SLARemove terminal area-fill closure zeros from the applicable SLA curves. Preserve mechanical minimum zero and apply a separate sizing convention. Keep the supplied legacy 3/16-inch model available in all internal calculators with current manufacturer confirmation pending; exclude it from public website pump selection. Use current Rev 03 for the SLA 1-1/2-inch: 1,400 PSIG and 3,000 lbf, with separately traced motor curves; exclude the pending extension above 1,400 PSIG.
Additional modelsFour LeakLess curve sets agree with the official PDF. ATP HP agrees with its supplied document, but independent current web confirmation is unresolved. All 14 MD, MDZ and S records are intentionally excluded from every selector and retained in the backend for reference. Their table ratings were checked, but pressure-dependent curves were not verified.

How the selection data should be interpreted

Chart precision

Curve coordinates are digitized approximations, not original test measurements. Extra stored decimal places do not establish that level of accuracy. ATP verification used a 5-pixel tolerance on 1300-pixel renderings; all 30 LeakLess knots agreed within 0.006 US gal/h.

Pressure and curve coverage

Enforce MAWP and the selected curve’s published pressure range independently. Interpolate only inside that range. A drawn point beyond MAWP, or an axis extending farther, does not authorize operation there.

Continuous-duty assumption

Automatic selection assumes continuous operation where a “Continuous Use” boundary is published. That line limits the usable duty; it is not an extra motor or supply option. Apply the selected configuration and the continuous boundary together.

SLA and LeakLess sizing minimum

Mechanical minimum remains zero. For sizing, use each selected curve’s maximum flow ÷ 40 as an explicit conservative calculator convention. The separate API accuracy guidance is 10–100% of maximum flow with viscosity up to 10 cP; zero stroke is not a metering-accuracy claim.

FXS solar capacity

The empirical charts describe full motor power. The standard selector retains its separate solar capacity cap from the overview table at insolation factor 7. A full-power hourly curve is not a guarantee of daily solar production.

Zero endpoints

Sloping pneumatic curves that reach zero and documented vertical supply boundaries are retained. Applicable SLA terminal zeros were area-fill closure artifacts. Vertical pneumatic boundary behavior remains subject to the source’s interpretation.

Current applicable manufacturer sources supersede outdated handover records and older reference documents. Use model-specific empirical curves ahead of quick-reference tables where the manufacturer explicitly directs this. Head material, rod force, supply conditions, RPM, gearbox and head count must match the selected configuration; genuine unresolved source conflicts remain flagged.

Open engineering review items

SLA 3/16-inch is available internally; current manufacturer confirmation is pending. All internal calculators retain the supplied legacy model. Public website pump selection continues to exclude it. Neither current Rev 03, prior Rev 02 nor the current product table establishes the supplied curves and 7,500-PSIG legacy rating; internal availability does not constitute current manufacturer verification.

All 97 reviewed model records

Open a model for ratings, findings, source pages and digitized curve points. These 97 records describe audit coverage, not the number offered by a selector. “Chart checked” means agreement at graph-reading precision. MD, MDZ and S are marked “Excluded · table only” and retained solely as backend reference. Other variants are not added by inference without applicable performance evidence.

Series 1250 12

Series 1250 1/8" GRChart checked
12,000 PSIG MAWP0.002 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-088 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
40 psi supply0 → 0.37544; 6,000 → 0.22971; 12,000 → 0.0741
100 psi supply0 → 0.4446; 6,000 → 0.33345; 12,000 → 0.25194
Series 1250 1/8" HPChart checked
12,000 PSIG MAWP0.002 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-016B REV. 25 EFF. DATE: 01 APR 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 0.47; 6,000 → 0.35; 12,000 → 0.27
40 psi supply0 → 0.43; 12,000 → 0.15
Series 1250 1/8"Chart checked
7,500 PSIG MAWP0.002 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-016A REV. 24 EFF. DATE: 01 APR 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 0.4; 7,500 → 0.16
40 psi supply0 → 0.28; 7,500 → 0.11
Series 1250 3/16" GRChart checked
7,500 PSIG MAWP0.007 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-086 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
40 psi supply0 → 0.87932; 2,000 → 0.65208; 5,800 → 0.04693; 5,800 → 0
100 psi supply0 → 0.99788; 2,000 → 0.82992; 6,000 → 0.61256; 7,600 → 0.5538
Series 1250 3/16"Chart checked
7,500 PSIG MAWP0.007 US gal/h minimum field1 published curve

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-017 REV. 22 EFF. DATE: 07 JUL 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 1.13; 2,250 → 0.74; 7,500 → 0.53
Series 1250 1/4" GRChart checked
12,000 PSIG MAWP0.013 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-089 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 1.82083; 6,000 → 0.692708; 8,800 → 0.0890625; 8,800 → 0
200 psi supply0 → 1.85; 6,000 → 1.10833; 12,000 → 0.554167; 12,000 → 0
Series 1250 1/4" HPChart checked
12,000 PSIG MAWP0.013 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-018B REV. 22 EFF. DATE: 01 APR 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 2; 12,000 → 0.5
100 psi supply0 → 2; 6,500 → 0.79; 10,000 → 0
Series 1250 1/4"Chart checked
7,500 PSIG MAWP0.013 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-018A REV. 23 EFF. DATE: 01 APR 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 2; 7,500 → 0.791667
100 psi supply0 → 2; 7,500 → 0.5
Series 1250 3/8" GRChart checked
7,500 PSIG MAWP0.05 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-087 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 3.8; 2,000 → 2.375; 3,900 → 0.00989583
200 psi supply0 → 4.23542; 2,000 → 3.29531; 8,000 → 0.346354
Series 1250 3/8"Chart checked
7,500 PSIG MAWP0.042 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-019 REV. 21 EFF. DATE: 01 APR 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 4.69; 6,600 → 1.71; 7,500 → 1.08; 9,000 → 0
100 psi supply0 → 4.69; 2,000 → 3.13; 4,600 → 0
Series 1250 1/2" GRChart checked
7,500 PSIG MAWP0.083 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-090 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 6.8875; 1,000 → 4.79948; 2,300 → 0.217708; 2,300 → 0
200 psi supply0 → 7.40208; 2,000 → 4.80938; 4,600 → 0.0791667; 4,600 → 0
Series 1250 1/2"Source conflict
7,500 PSIG MAWP0.083 US gal/h minimum field2 published curves

Handover

  • Current family table lists 5000 PSIG while the specific Rev23 performance PDF footer says 7500 PSIG. Retain chart MAWP with an explicit source-conflict flag; both supply curves stall at or below 5000, so flow availability still prevents duty beyond the plotted range.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-021 REV. 23 EFF. DATE: 01 APR 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 8; 2,500 → 5.04; 3,900 → 3.33; 5,000 → 0
100 psi supply0 → 7.92; 1,100 → 5.42; 2,700 → 0

Series 1500 10

Series 1500 3/8" GRChart checked
15,000 PSIG MAWP0.05 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-081 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 1.33594; 7,500 → 0.900521; 15,000 → 0.465104
200 psi supply0 → 1.33; 7,500 → 1.02917; 15,000 → 0.7125
Series 1500 3/8" HPSource conflict
15,000 PSIG MAWP0.05 US gal/h minimum field2 published curves

Handover

  • Chart minimum is 0.05 USG/H but its parenthetical metric minimum is 0.16 L/H; these are inconsistent. Preserve printed USG/H and calculate metric conversions rather than copying the conflicting 0.16. Current family table minimum is 0.041.

Performance PDF · page 1 DOC ID: CP/CHA-ENG-022B REV. 13 EFF. DATE: 07/11/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 2.21; 15,000 → 0.42
100 psi supply0 → 2.21; 15,000 → 0.13
Series 1500 1/2" GRChart checked
10,000 PSIG MAWP0.062 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-084 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 2.81042; 7,600 → 0.910417; 9,200 → 0.0791667; 9,200 → 0
200 psi supply0 → 2.81; 7,600 → 1.78125; 10,000 → 1.425
Series 1500 1/2"Corrected
10,000 PSIG MAWP0.062 US gal/h minimum field2 published curves

Handover

  • Current Rev14 vector chart has initial flow approximately 3.20 GPH, 200 psi endpoint approximately 1.75 GPH, and 100 psi knee approximately 1.64 GPH. Handover 3.42/1.88/1.75 came from a different scale or table.
  • Family quick table lists max 3.42 GPH, while specific Rev14 performance graph begins around 3.2. Use the plotted performance curve for sizing.

Performance PDF · page 1 DOC ID: CP/CHA-ENG-023 REV. 14 EFF. DATE: 07/11/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 3.2; 10,000 → 1.75
100 psi supply0 → 3.2; 7,500 → 1.64; 10,000 → 0
Series 1500 3/4" GRChart checked
9,000 PSIG MAWP0.13 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-082 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 5.89792; 2,400 → 3.75052; 4,300 → 0
200 psi supply0 → 5.89; 2,400 → 4.65104; 8,600 → 0.0752083; 8,600 → 0
Series 1500 3/4"Chart checked
9,000 PSIG MAWP0.13 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CP/CHA-ENG-024 REV. 13 EFF. DATE: 07/11/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 9.58; 6,800 → 3.25; 9,000 → 0
100 psi supply0 → 9.58; 3,400 → 3.79; 4,700 → 0
Series 1500 1" GRChart checked
5,000 PSIG MAWP0.79 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-085 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 11.1625; 1,000 → 7.65937; 2,200 → 2.79062; 2,400 → 0
200 psi supply0 → 11.16; 1,000 → 9.30208; 4,000 → 3.8; 4,800 → 0
Series 1500 1"Chart checked
5,000 PSIG MAWP0.79 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CP/CHA-ENG-025 REV. 13 EFF. DATE: 07/11/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 16.04; 3,800 → 7.5; 5,000 → 0
100 psi supply0 → 16.04; 2,000 → 7.92; 2,600 → 0
Series 1500 1-1/2" GRChart checked
2,250 PSIG MAWP1.42 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 DOC ID: CPHQ/CHA-MRK-083 REV. 00 EFF. DATE: 27 OCT 2025 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
100 psi supply0 → 25.1473; 400 → 17.2742; 600 → 2.0049; 600 → 0
200 psi supply0 → 25.2; 1,000 → 15.6869; 2,000 → 5.00729
Series 1500 1-1/2"Corrected
2,250 PSIG MAWP1.42 US gal/h minimum field2 published curves

Handover

  • Printed Rev12 maximum pressure is 2250 PSIG, already stated correctly in the handover footer. Handover numeric MAWP 2500 was the axis maximum, not the printed rating.
  • Current family quick table states 2275 PSIG, specific Rev12 chart footer states 2250. Use the model-specific chart rating 2250.

Performance PDF · page 1 DOC ID: CP/CHA-ENG-026 REV. 12 EFF. DATE: 07/11/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 36.04; 1,775 → 15.21; 2,250 → 0
100 psi supply0 → 35.83; 550 → 23.75; 1,100 → 0

Series 5400 5

Series 5408 1/2"Chart checked
15,000 PSIG MAWP0.83 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 Rev CP/CHA-ENG-027 REV. 09 EFF. DATE: 07/12/2022 Page 1 of 1 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
150 psi supply0 → 27; 15,000 → 1; 15,000 → 0
100 psi supply0 → 26.9; 10,000 → 1; 10,000 → 0
Series 5412 3/4"Chart checked
6,500 PSIG MAWP3 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 Rev CP/CHA-ENG-028 REV. 10 EFF. DATE: 07/12/2022 Page 1 of 1 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 123; 6,500 → 8; 6,500 → 0
100 psi supply0 → 117.5; 4,500 → 10; 4,500 → 0
Series 5416 1"Chart checked
5,200 PSIG MAWP7 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 Rev CP/CHA-ENG-029 REV. 10 EFF. DATE: 07/12/2022 Page 1 of 1 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 220; 5,300 → 20; 5,300 → 0
100 psi supply0 → 208; 2,800 → 10; 2,800 → 0
Series 5428 1-3/4"Chart checked
1,775 PSIG MAWP19 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 Rev CP/CHA-ENG-030 REV. 10 EFF. DATE: 07/12/2022 Page 1 of 1 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 640; 1,800 → 0
100 psi supply0 → 640; 300 → 500; 700 → 220; 800 → 0
Series 5440 2-1/2"Chart checked
650 PSIG MAWP40 US gal/h minimum field2 published curves

Handover

  • No material discrepancy identified at chart-reading precision.

Performance PDF · page 1 Rev CP/CHA-ENG-031 REV. 11 EFF. DATE: 07/12/2022 Page 1 of 1 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 1,160; 250 → 890; 550 → 445; 650 → 0
100 psi supply0 → 1,050; 200 → 525; 300 → 0

Series 6200 1

Series 6212 3/4"Corrected
10,000 PSIG MAWP1.8 US gal/h minimum field2 published curves

Handover

  • Current Rev08 high curve is explicitly 150 PSIG supply, not 200. Convert the verified 10000 PSIG MAWP to 689.5 BARG.

Performance PDF · page 1 Rev CP/CHA-ENG-032 REV. 08 EFF. DATE: 07/13/2022 Page 1 of 1 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
150 psi supply0 → 58; 9,500 → 0
100 psi supply0 → 58; 6,400 → 0

Series 8400 5

Series 8408 1/2"Corrected
20,000 PSIG MAWP0.83 US gal/h minimum field2 published curves

Handover

  • Current product-page Rev13 supersedes the linked hub Rev12 reference. Printed high supply is 150 PSIG and minimum 0.83 GPH. Both curves begin approximately 11.8 GPH; digitized knees are approximately 12000/9.3 (high) and 11300/9.45, 14000/8 (low).
  • Current family quick table minimum 0.82 differs from specific Rev13 chart 0.83. Table maximum 15.2 GPH is not supported by the 100/150 psi curves that begin around 11.8. Do not fabricate a 200 psi curve from the table.

Performance PDF · page 1 Rev CP/CHA-ENG-033 REV. 13 EFF. DATE: 07/14/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
150 psi supply0 → 11.8; 12,000 → 9.3; 20,000 → 8
100 psi supply0 → 11.8; 11,300 → 9.45; 14,000 → 8; 20,000 → 7.15
Series 8412 3/4"Corrected
20,000 PSIG MAWP3 US gal/h minimum field2 published curves

Handover

  • Current Rev14 high curve is explicitly 175 PSIG supply, not 200.
  • Family quick table max 56 GPH exceeds the plotted 100/175 psi curve start around 42.5. Do not invent a 200 psi curve or rescale to table maximum.

Performance PDF · page 1 Rev CP/CHA-ENG-034 REV. 14 EFF. DATE: 07/14/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
175 psi supply0 → 42.5; 1,000 → 38.9; 15,000 → 17.3; 20,000 → 3
100 psi supply0 → 42.5; 1,000 → 39; 6,000 → 25; 9,000 → 16; 11,500 → 0
Series 8416 1"Corrected
12,750 PSIG MAWP7 US gal/h minimum field2 published curves

Handover

  • Current Rev13 performance chart explicitly states minimum 7 GPH. Product-page quick table states 3.7; chart governs performance sizing. Verified 12750 PSIG converts to 879.1 BARG, not 879.4.
  • Family quick table min/max 3.7/87.75 GPH differs from chart minimum 7 and plotted maximum around 75. MAWP 12750 PSIG is the table rating; the graph continues slightly beyond it.

Performance PDF · page 1 Rev CP/CHA-ENG-035 REV. 13 EFF. DATE: 07/14/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 75; 5,500 → 56; 13,000 → 0
100 psi supply0 → 75; 3,000 → 58; 6,400 → 0
Series 8428 1-3/4"Corrected
4,000 PSIG MAWP19 US gal/h minimum field2 published curves

Handover

  • Current Rev09 performance chart explicitly states minimum 19 GPH. Product-page quick table states 17; chart governs performance sizing.
  • Family quick table min/max 17/327 GPH differs from chart minimum 19 and plotted maximum around 245.

Performance PDF · page 1 Rev CP/CHA-ENG-036 REV. 09 EFF. DATE: 07/14/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 245; 4,000 → 0
100 psi supply0 → 230; 1,500 → 120; 2,000 → 0
Series 8440 2-1/2"Corrected
2,075 PSIG MAWP40 US gal/h minimum field2 published curves

Handover

  • Current Rev10 performance chart explicitly states minimum 40 GPH (quick table 35). The high curve reaches approximately 44 GPH at the vertical boundary around 2075 psi, not 30 GPH at 2100; preserve the depicted vertical zero endpoint. Verified 2075 PSIG converts to 143.1 BARG.
  • Family quick table min/max 35/654 GPH differs from chart minimum 40 and plotted maximum around 590.

Performance PDF · page 1 Rev CP/CHA-ENG-037 REV. 10 EFF. DATE: 07/14/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
200 psi supply0 → 590; 1,500 → 260; 2,075 → 44; 2,075 → 0
100 psi supply0 → 500; 720 → 300; 1,050 → 0

Series GX15 1

Series GX15 1/4"Corrected
3,500 PSIG MAWP0.04 US gal/h minimum field2 published curves

Handover

  • Current Rev09 red curve has approximately 0.89 GPH at 2000 psi, 0.66 at 3000 and 0.44 at 3500; blue branches around 1550 psi at 0.94 GPH. Replace copied electric-motor/rod-force/stroke boilerplate with the official pneumatic chart footer.

Performance PDF · page 1 Rev CP/CHA-ENG-038 REV. 09 EFF. DATE: 07/14/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
150 psi supply0 → 1.46; 1,000 → 1; 2,000 → 0.89; 3,000 → 0.66; 3,500 → 0.44
100 psi supply0 → 1.46; 1,000 → 1; 1,550 → 0.94; 2,000 → 0.7; 2,500 → 0.51; 3,000 → 0

Series ATP 18

Series ATP 1/2" Dual Head - 120VAC FixedChart checked
2,200 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 4 CPHQ-CHA-MRK-051 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 4.2; 500 → 4.08; 2,000 → 3.78; 2,200 → 3.66
Series ATP 1/2" Dual Head - 120VAC ModularCorrected
2,200 PSIG MAWP0 US gal/h minimum field4 published curves

Handover

  • Replace both 28.88:1 curve labels with 27.55:1; retain 13.18:1 labels and all points.
  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 8 CPHQ/CHA-MRK-050 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750 RPM, 13.18:10 → 8.8; 1,000 → 8.4; 2,200 → 8.2
1450 RPM, 13.18:10 → 7.2; 1,000 → 7; 2,200 → 6.84
1750 RPM, 27.55:10 → 4.6; 1,000 → 4.4; 2,200 → 4.3
1450 RPM, 27.55:10 → 3.8; 1,000 → 3.6; 2,200 → 3.58
Series ATP 1/2" Dual Head - 12VDCChart checked
2,200 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 4 CPHQ-CHA-MRK-052 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 4.76; 500 → 4.62; 2,000 → 4.28; 2,200 → 4.16
Series ATP 1/2" Single Head - 120VAC FixedChart checked
2,200 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 3 CPHQ-CHA-MRK-051 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 2.1; 500 → 2.04; 2,000 → 1.89; 2,200 → 1.83
Series ATP 1/2" Single Head - 120VAC ModularCorrected
2,200 PSIG MAWP0 US gal/h minimum field4 published curves

Handover

  • Replace both 28.88:1 curve labels with 27.55:1; retain 13.18:1 labels and all points.
  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 7 CPHQ/CHA-MRK-050 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750 RPM, 13.18:10 → 4.4; 1,000 → 4.2; 2,200 → 4.1
1450 RPM, 13.18:10 → 3.6; 1,000 → 3.5; 2,200 → 3.42
1750 RPM, 27.55:10 → 2.3; 1,000 → 2.2; 2,200 → 2.15
1450 RPM, 27.55:10 → 1.9; 1,000 → 1.8; 2,200 → 1.79
Series ATP 1/2" Single Head - 12VDCChart checked
2,200 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 3 CPHQ-CHA-MRK-052 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 2.38; 500 → 2.31; 2,000 → 2.14; 2,200 → 2.08
Series ATP 1/4" Dual Head - 120VAC FixedChart checked
5,000 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 2 CPHQ-CHA-MRK-051 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 1.13; 1,000 → 0.73; 3,000 → 0.662; 5,000 → 0.62
Series ATP 1/4" Dual Head - 120VAC ModularCorrected
5,000 PSIG MAWP0 US gal/h minimum field4 published curves

Handover

  • Replace both 28.88:1 curve labels with 27.55:1; retain 13.18:1 labels and all points.
  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 2 CPHQ/CHA-MRK-050 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750 RPM, 13.18:1 Gear Ratio0 → 2.08; 2,000 → 1.76; 5,000 → 1.44
1450 RPM, 13.18:1 Gear Ratio0 → 1.74; 2,000 → 1.46; 5,000 → 1.2
1750 RPM, 27.55:1 Gear Ratio0 → 1.06; 2,000 → 0.92; 5,000 → 0.76
1450 RPM, 27.55:1 Gear Ratio0 → 0.88; 2,000 → 0.77; 5,000 → 0.62
Series ATP 1/4" Dual Head - 12VDCChart checked
5,000 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 2 CPHQ-CHA-MRK-052 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 1.14; 1,000 → 0.912; 2,000 → 0.796; 3,000 → 0.74; 4,000 → 0.71; 5,000 → 0.55
Series ATP 1/4" Single Head - 120VAC FixedChart checked
5,000 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 1 CPHQ-CHA-MRK-051 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 0.565; 1,000 → 0.365; 3,000 → 0.331; 5,000 → 0.31
Series ATP 1/4" Single Head - 120VAC ModularCorrected
5,000 PSIG MAWP0 US gal/h minimum field4 published curves

Handover

  • Replace both 28.88:1 curve labels with 27.55:1; retain 13.18:1 labels and all points.
  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 1 CPHQ/CHA-MRK-050 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750 RPM, 13.18:1 Gear Ratio0 → 1.04; 2,000 → 0.88; 5,000 → 0.72
1450 RPM, 13.18:1 Gear Ratio0 → 0.87; 2,000 → 0.73; 5,000 → 0.6
1750 RPM, 27.55:1 Gear Ratio0 → 0.53; 2,000 → 0.46; 5,000 → 0.38
1450 RPM, 27.55:1 Gear Ratio0 → 0.44; 2,000 → 0.385; 5,000 → 0.31
Series ATP 1/4" Single Head - 12VDCChart checked
5,000 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 1 CPHQ-CHA-MRK-052 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 0.57; 1,000 → 0.456; 2,000 → 0.398; 3,000 → 0.37; 4,000 → 0.355; 5,000 → 0.275
Series ATP 3/8" Dual Head - 120VAC FixedChart checked
3,500 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 6 CPHQ-CHA-MRK-051 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 2.44; 500 → 2.34; 2,000 → 2.2; 3,500 → 2.16
Series ATP 3/8" Dual Head - 120VAC ModularCorrected
3,500 PSIG MAWP0 US gal/h minimum field4 published curves

Handover

  • Replace both 28.88:1 curve labels with 27.55:1; retain 13.18:1 labels and all points.
  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 5 CPHQ/CHA-MRK-050 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750 RPM, 13.18:10 → 4.84; 3,000 → 4.36; 3,500 → 4.26
1450 RPM, 13.18:10 → 4; 3,000 → 3.6; 3,500 → 3.56
1750 RPM, 27.55:10 → 2.56; 3,000 → 2.2; 3,500 → 2.16
1450 RPM, 27.55:10 → 2.16; 3,000 → 1.84; 3,500 → 1.8
Series ATP 3/8" Dual Head - 12VDCChart checked
3,500 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 6 CPHQ-CHA-MRK-052 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 2.76; 500 → 2.66; 2,000 → 2.5; 3,500 → 2.44
Series ATP 3/8" Single Head - 120VAC FixedChart checked
3,500 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 5 CPHQ-CHA-MRK-051 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 1.22; 500 → 1.17; 2,000 → 1.1; 3,500 → 1.08
Series ATP 3/8" Single Head - 120VAC ModularCorrected
3,500 PSIG MAWP0 US gal/h minimum field4 published curves

Handover

  • Replace both 28.88:1 curve labels with 27.55:1; retain 13.18:1 labels and all points.
  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 4 CPHQ/CHA-MRK-050 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750 RPM, 13.18:10 → 2.42; 3,000 → 2.18; 3,500 → 2.13
1450 RPM, 13.18:10 → 2; 3,000 → 1.8; 3,500 → 1.78
1750 RPM, 27.55:10 → 1.28; 3,000 → 1.1; 3,500 → 1.08
1450 RPM, 27.55:10 → 1.08; 3,000 → 0.92; 3,500 → 0.9
Series ATP 3/8" Single Head - 12VDCChart checked
3,500 PSIG MAWP0 US gal/h minimum field1 published curve

Handover

  • MAWP is the plotted pressure maximum and agrees with current empirical source.
  • Zero minimum is mechanical zero-stroke control, not a claim of nonzero metering accuracy.

Performance PDF · page 5 CPHQ-CHA-MRK-052 · Rev 01 · Effective 01 May 2025 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 1.38; 500 → 1.33; 2,000 → 1.25; 3,500 → 1.22

Series FXA 12

Series FXA 1250 1/4" - VFD ControlChart checked
7,500 PSIG MAWP0.038 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.

Performance PDF · page 3 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 1.036; 2,000 → 0.8783; 6,000 → 0.6589; 7,500 → 0.6417
1750RPM Motor w/ 27.55 Reducer0 → 0.5431; 2,000 → 0.4622; 6,000 → 0.3503; 7,500 → 0.3418
1450RPM Motor w/ 13.18 Reducer0 → 0.8665; 2,000 → 0.7333; 6,000 → 0.5536; 7,500 → 0.5445
1450RPM Motor w/ 27.55 Reducer0 → 0.446; 2,000 → 0.3842; 6,000 → 0.2841; 7,500 → 0.278
Series FXA 1250 1/8" HP - VFD ControlChart checked
12,000 PSIG MAWP0.01 US gal/h minimum field5 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.
  • Continuous Use is a duty envelope, not another motor/reducer option. Use this boundary for continuous-duty selection.

Performance PDF · page 1 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Continuous Use0 → 0.063; 12,000 → 0.0347
1750RPM Motor w/ 13.18 Reducer0 → 0.2492; 12,000 → 0.1295
1750RPM Motor w/ 27.55 Reducer0 → 0.1291; 12,000 → 0.0682
1450RPM Motor w/ 13.18 Reducer0 → 0.2085; 12,000 → 0.1087
1450RPM Motor w/ 27.55 Reducer0 → 0.1088; 12,000 → 0.0556
Series FXA 1250 1/8" - VFD ControlChart checked
7,500 PSIG MAWP0.01 US gal/h minimum field5 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.
  • Continuous Use is a duty envelope, not another motor/reducer option. Use this boundary for continuous-duty selection.

Performance PDF · page 1 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Continuous Use0 → 0.063; 7,500 → 0.0453
1750RPM Motor w/ 13.18 Reducer0 → 0.2492; 7,500 → 0.1744
1750RPM Motor w/ 27.55 Reducer0 → 0.1291; 7,500 → 0.091
1450RPM Motor w/ 13.18 Reducer0 → 0.2085; 7,500 → 0.1461
1450RPM Motor w/ 27.55 Reducer0 → 0.1088; 7,500 → 0.0755
Series FXA 1250 3/16" - VFD ControlChart checked
7,500 PSIG MAWP0.022 US gal/h minimum field5 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.
  • Continuous Use is a duty envelope, not another motor/reducer option. Use this boundary for continuous-duty selection.

Performance PDF · page 2 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Continuous Use0 → 0.1445; 7,500 → 0.0926
1750RPM Motor w/ 13.18 Reducer0 → 0.5793; 6,000 → 0.4006; 7,500 → 0.3703
1750RPM Motor w/ 27.55 Reducer0 → 0.3024; 6,000 → 0.2071; 7,500 → 0.1911
1450RPM Motor w/ 13.18 Reducer0 → 0.4794; 6,000 → 0.3296; 7,500 → 0.3045
1450RPM Motor w/ 27.55 Reducer0 → 0.2506; 6,000 → 0.1711; 7,500 → 0.1584
Series FXA 1250 1/4" HP - VFD ControlChart checked
12,000 PSIG MAWP0.038 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.

Performance PDF · page 3 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 1.036; 2,000 → 0.8783; 6,000 → 0.6589; 12,000 → 0.5899
1750RPM Motor w/ 27.55 Reducer0 → 0.5431; 2,000 → 0.4622; 6,000 → 0.3503; 12,000 → 0.3165
1450RPM Motor w/ 13.18 Reducer0 → 0.8665; 2,000 → 0.7333; 6,000 → 0.5536; 12,000 → 0.5174
1450RPM Motor w/ 27.55 Reducer0 → 0.446; 2,000 → 0.3842; 6,000 → 0.2841; 12,000 → 0.2597
Series FXA 1250 3/8" - VFD ControlChart checked
7,500 PSIG MAWP0.086 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.

Performance PDF · page 4 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 2.424; 3,000 → 2.163; 6,000 → 1.986; 7,500 → 1.917
1750RPM Motor w/ 27.55 Reducer0 → 1.285; 3,000 → 1.09; 6,000 → 1.028; 7,500 → 1.002
1450RPM Motor w/ 13.18 Reducer0 → 2.001; 3,000 → 1.795; 6,000 → 1.646; 7,500 → 1.597
1450RPM Motor w/ 27.55 Reducer0 → 1.065; 3,000 → 0.917; 6,000 → 0.855; 7,500 → 0.8122
Series FXA 1250 1/2" - VFD ControlChart checked
7,500 PSIG MAWP0.153 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.

Performance PDF · page 5 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 4.38; 1,000 → 4.192; 3,000 → 4.014; 7,500 → 3.839
1750RPM Motor w/ 27.55 Reducer0 → 2.3; 1,000 → 2.203; 3,000 → 2.106; 7,500 → 2.009
1450RPM Motor w/ 13.18 Reducer0 → 3.611; 1,000 → 3.489; 3,000 → 3.37; 7,500 → 3.201
1450RPM Motor w/ 27.55 Reducer0 → 1.906; 1,000 → 1.815; 3,000 → 1.774; 7,500 → 1.709
Series FXA 1500 3/8" HP - VFD ControlChart checked
15,000 PSIG MAWP0.086 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.

Performance PDF · page 6 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 2.426; 3,000 → 2.176; 8,000 → 1.901; 15,000 → 1.901
1750RPM Motor w/ 27.55 Reducer0 → 1.29; 3,000 → 1.118; 8,000 → 1.007; 15,000 → 1.005
1450RPM Motor w/ 13.18 Reducer0 → 2.001; 3,000 → 1.804; 8,000 → 1.603; 15,000 → 1.603
1450RPM Motor w/ 27.55 Reducer0 → 1.056; 3,000 → 0.9308; 8,000 → 0.825; 15,000 → 0.8197
Series FXA 1500 1/2" - VFD ControlChart checked
10,000 PSIG MAWP0.153 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.
  • Material correction: supplied flow/pressure scaling is wrong. Current page 7 has about 4.37 GPH at zero PSI and 3.17 GPH at 10,000 PSI for 1750 RPM/13.18:1; knots are 0, 4,000 and 10,000 PSI. Handover has 2.625 GPH and a 15,000-PSI endpoint. Keep 10,000-PSI MAWP and replace all four curves.

Performance PDF · page 7 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 4.366; 4,000 → 3.662; 10,000 → 3.173
1750RPM Motor w/ 27.55 Reducer0 → 2.3; 4,000 → 1.916; 10,000 → 1.667
1450RPM Motor w/ 13.18 Reducer0 → 3.609; 4,000 → 3.007; 10,000 → 2.642
1450RPM Motor w/ 27.55 Reducer0 → 1.922; 4,000 → 1.566; 10,000 → 1.381
Series FXA 1500 3/4" - VFD ControlChart checked
4,500 PSIG MAWP0.344 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.
  • Material secondary-curve difference at 4,500 PSI: drawn 1750/27.55 is about 4.82 GPH, not supplied 4.62; drawn 1450/13.18 is about 7.51 GPH, not supplied 7.32.

Performance PDF · page 8 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 9.944; 2,000 → 9.275; 4,500 → 8.818
1750RPM Motor w/ 27.55 Reducer0 → 5.203; 2,000 → 4.886; 4,500 → 4.821
1450RPM Motor w/ 13.18 Reducer0 → 8.208; 2,000 → 7.712; 4,500 → 7.505
1450RPM Motor w/ 27.55 Reducer0 → 4.269; 2,000 → 4.018; 4,500 → 3.758
Series FXA 1500 1" - VFD ControlChart checked
2,500 PSIG MAWP0.612 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.

Performance PDF · page 9 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 17.95; 1,000 → 16.87; 2,500 → 16.67
1750RPM Motor w/ 27.55 Reducer0 → 9.289; 1,000 → 8.808; 2,500 → 8.747
1450RPM Motor w/ 13.18 Reducer0 → 14.92; 1,000 → 13.99; 2,500 → 13.9
1450RPM Motor w/ 27.55 Reducer0 → 7.766; 1,000 → 7.266; 2,500 → 7.197
Series FXA 1500 1-1/2" - VFD ControlChart checked
1,100 PSIG MAWP1.377 US gal/h minimum field4 published curves

Handover

  • MAWP and stated minimum flow agree with current performance PDF. Motor/reducer labels confirmed as 1750 or 1450 RPM with 13.18:1 or 27.55:1. Each drawn motor path traced independently; supplied ratio-scaled secondary paths sometimes differ visibly.

Performance PDF · page 10 CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18 Reducer0 → 40.91; 550 → 38.68; 1,100 → 38.15
1750RPM Motor w/ 27.55 Reducer0 → 21.32; 550 → 20.07; 1,100 → 20
1450RPM Motor w/ 13.18 Reducer0 → 33.73; 550 → 31.96; 1,100 → 31.77
1450RPM Motor w/ 27.55 Reducer0 → 17.81; 550 → 16.51; 1,100 → 16.35

Series FXS 8

Series FXS 1250 1/8"Chart checked
12,000 PSIG MAWP0.014 US gal/h minimum field2 published curves

Handover

  • Explicit current minimum-flow label agrees with handover.
  • Motor MAWP agrees. Head rating is separately reported and does not increase the motor-limited operating range.
  • Current continuous-use line is drawn only from 0 to about 4,000 PSI. The retained continuation follows the lower maximum-flow line after the intersection: a derived operating envelope, not a separately drawn test curve.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 1 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Continuous Use0 → 0.12; 4,000 → 0.113; 8,000 → 0.07; 10,000 → 0.055; 12,000 → 0.043
Maximum Flow0 → 0.16; 1,000 → 0.145; 8,000 → 0.07; 10,000 → 0.055; 12,000 → 0.043
Series FXS 1250 3/16"Chart checked
7,500 PSIG MAWP0.032 US gal/h minimum field2 published curves

Handover

  • Explicit current minimum-flow label corrects 0.033 to 0.032 US gal/hr.
  • Motor MAWP agrees. Head rating is separately reported and does not increase the motor-limited operating range.
  • Added omitted source vertex/vertices; these are approximate graph readings.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 2 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Continuous Use0 → 0.15; 7,500 → 0.12
Maximum Flow0 → 0.361; 2,000 → 0.321; 4,000 → 0.29; 6,000 → 0.259; 7,500 → 0.243
Series FXS 1250 1/4"Chart checked
7,500 PSIG MAWP0.057 US gal/h minimum field1 published curve

Handover

  • Explicit current minimum-flow label corrects 0.061 to 0.057 US gal/hr.
  • Motor MAWP agrees. Head rating is separately reported and does not increase the motor-limited operating range.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 3 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 0.641; 1,000 → 0.568; 3,000 → 0.463; 4,000 → 0.438; 7,500 → 0.393
Series FXS 1250 3/8"Chart checked
3,250 PSIG MAWP0.129 US gal/h minimum field1 published curve

Handover

  • Explicit current minimum-flow label corrects 0.104 to 0.129 US gal/hr.
  • Current performance PDF motor limit 3,300 PSI conflicts with webpage/handover 3,250 PSI. Keep the lower existing limit and interpolate the terminal flow at that limit. Do not infer the motor limit from the higher hydraulic-head rating.
  • Added omitted source vertex/vertices; these are approximate graph readings.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 4 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 1.443; 500 → 1.391; 1,500 → 1.301; 2,000 → 1.277; 3,250 → 1.226
Series FXS 1250 1/2"Chart checked
1,850 PSIG MAWP0.229 US gal/h minimum field1 published curve

Handover

  • Explicit current minimum-flow label corrects 0.236 to 0.229 US gal/hr.
  • Current performance PDF motor limit 1,900 PSI conflicts with webpage/handover 1,850 PSI. Keep the lower existing limit and interpolate the terminal flow at that limit. Do not infer the motor limit from the higher hydraulic-head rating.
  • Added omitted source vertex/vertices; these are approximate graph readings.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 5 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 2.567; 500 → 2.479; 1,000 → 2.415; 1,850 → 2.3291
Series FXS 1500 3/4"Chart checked
800 PSIG MAWP0.516 US gal/h minimum field1 published curve

Handover

  • Explicit current minimum-flow label agrees with handover.
  • Motor MAWP agrees. Head rating is separately reported and does not increase the motor-limited operating range.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 6 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 5.772; 350 → 5.326; 800 → 5.025
Series FXS 1500 1"Chart checked
400 PSIG MAWP0.918 US gal/h minimum field1 published curve

Handover

  • Explicit current minimum-flow label agrees with handover.
  • Motor MAWP agrees. Head rating is separately reported and does not increase the motor-limited operating range.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 7 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 10.262; 200 → 9.639; 400 → 9.21
Series FXS 1500 1-1/2"Chart checked
200 PSIG MAWP2.065 US gal/h minimum field1 published curve

Handover

  • Explicit current minimum-flow label agrees with handover.
  • Motor MAWP agrees. Head rating is separately reported and does not increase the motor-limited operating range.
  • Handover footer incorrectly used FXA motor/rod-force details. Current FXS document states 375 lbf and a 12 VDC variable-speed motor. Full-power curves and solar daily-capacity tables have different power assumptions; preserve and label solar-table limits separately.

Performance PDF · page 8 DOC-FXS-FLOW-CURVES · Rev 00 Source record

Product page Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
Maximum Flow0 → 23.106; 100 → 22.034; 200 → 21.243

Series SLA 6

Series SLA 3/16"Internal · confirmation pending
7,500 PSIG legacy rating (unverified)0 US gal/h minimum field2 retained legacy curves

Handover

  • Retain the supplied legacy minimum of 0 US gal/h and both curves for internal use. The SLA sizing convention uses each curve maximum ÷ 40 as a conservative calculator floor, not a newly confirmed manufacturer minimum for this model.
  • Current manufacturer confirmation is pending: SLA 3/16-inch has no matching performance page in current Rev 03 or prior Rev 02, and no current product-table entry. Parts or model-code references do not verify these supplied curves or the 7,500-PSIG legacy rating. The model remains available in all internal calculators and excluded from the public website pump selector.

Product page Source record

Performance PDF CPHQ-CHA-ENG-014 · Rev 03 · Effective 08/APRIL/2026 Source record

Supplied legacy curve labels and points

Pressure in PSIG → approximate flow in US gal/h, retained from the supplied legacy data. Current manufacturer confirmation of these curves and the 7,500-PSIG legacy rating remains pending.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.022125 US gal/h (curve maximum ÷ 40).0 → 0.885; 2,000 → 0.755; 4,000 → 0.719; 6,000 → 0.693; 7,500 → 0.661
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.018332 US gal/h (curve maximum ÷ 40).0 → 0.733286; 2,000 → 0.625571; 4,000 → 0.595743; 6,000 → 0.5742; 7,500 → 0.547686
Series SLA 3/8"Chart checked
13,500 PSIG MAWP0 US gal/h minimum field2 published curves

Handover

  • Keep mechanical minFlow=0; the product page explicitly supports zero minimum for regular operation. Add each curve sizingMinFlow=max(source curve flows)/40 as a conservative calculator convention, not an exact manufacturer minimum. The performance footer separately recommends 40:1 sizing and 10–100% flow for API accuracy at viscosity up to 10 cP.
  • MAWP, 15:1 motor labels and operating points agree with the current performance chart within graph precision. Terminal vertical drops to zero are filled-chart boundary lines, not additional duty points; removed duplicate-pressure zero endpoints.

Product page Source record

Performance PDF · page 1 CPHQ-CHA-ENG-014 · Rev 03 · Effective 08/APRIL/2026 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.0795 US gal/h (curve maximum ÷ 40).0 → 3.18; 3,000 → 2.89; 12,000 → 2.35; 13,500 → 2.35
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.065871 US gal/h (curve maximum ÷ 40).0 → 2.63486; 3,000 → 2.39457; 12,000 → 1.94714; 13,500 → 1.94714
Series SLA 1/2"Chart checked
7,600 PSIG MAWP0 US gal/h minimum field2 published curves

Handover

  • Keep mechanical minFlow=0; the product page explicitly supports zero minimum for regular operation. Add each curve sizingMinFlow=max(source curve flows)/40 as a conservative calculator convention, not an exact manufacturer minimum. The performance footer separately recommends 40:1 sizing and 10–100% flow for API accuracy at viscosity up to 10 cP.
  • MAWP, 15:1 motor labels and operating points agree with the current performance chart within graph precision. Terminal vertical drops to zero are filled-chart boundary lines, not additional duty points; removed duplicate-pressure zero endpoints.
  • Quick-reference product table states 5.95 GPH maximum; performance curve and handover support about 5.65 GPH. Prefer performance PDF, as the webpage instructs.

Product page Source record

Performance PDF · page 2 CPHQ-CHA-ENG-014 · Rev 03 · Effective 08/APRIL/2026 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.14125 US gal/h (curve maximum ÷ 40).0 → 5.65; 2,000 → 5.08; 4,000 → 4.67; 7,600 → 4.06
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.117036 US gal/h (curve maximum ÷ 40).0 → 4.68143; 2,000 → 4.20914; 4,000 → 3.86943; 7,600 → 3.364
Series SLA 3/4"Chart checked
3,300 PSIG MAWP0 US gal/h minimum field2 published curves

Handover

  • Keep mechanical minFlow=0; the product page explicitly supports zero minimum for regular operation. Add each curve sizingMinFlow=max(source curve flows)/40 as a conservative calculator convention, not an exact manufacturer minimum. The performance footer separately recommends 40:1 sizing and 10–100% flow for API accuracy at viscosity up to 10 cP.
  • MAWP, 15:1 motor labels and operating points agree with the current performance chart within graph precision. Terminal vertical drops to zero are filled-chart boundary lines, not additional duty points; removed duplicate-pressure zero endpoints.

Product page Source record

Performance PDF · page 3 CPHQ-CHA-ENG-014 · Rev 03 · Effective 08/APRIL/2026 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.318 US gal/h (curve maximum ÷ 40).0 → 12.72; 1,000 → 12.18; 2,000 → 11.78; 3,300 → 11.47
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.263486 US gal/h (curve maximum ÷ 40).0 → 10.5394; 1,000 → 10.092; 2,000 → 9.76057; 3,300 → 9.50371
Series SLA 1"Chart checked
1,900 PSIG MAWP0 US gal/h minimum field2 published curves

Handover

  • Keep mechanical minFlow=0; the product page explicitly supports zero minimum for regular operation. Add each curve sizingMinFlow=max(source curve flows)/40 as a conservative calculator convention, not an exact manufacturer minimum. The performance footer separately recommends 40:1 sizing and 10–100% flow for API accuracy at viscosity up to 10 cP.
  • MAWP, 15:1 motor labels and operating points agree with the current performance chart within graph precision. Terminal vertical drops to zero are filled-chart boundary lines, not additional duty points; removed duplicate-pressure zero endpoints.

Product page Source record

Performance PDF · page 4 CPHQ-CHA-ENG-014 · Rev 03 · Effective 08/APRIL/2026 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.56525 US gal/h (curve maximum ÷ 40).0 → 22.61; 1,000 → 21.52; 1,900 → 21.32
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.46835 US gal/h (curve maximum ÷ 40).0 → 18.734; 1,000 → 17.8309; 1,900 → 17.6651
Series SLA 1-1/2"Updated to Rev 03
1,400 PSIG MAWP3,000 lbf rod force0 US gal/h minimum field2 independently traced curves

Handover model · current manufacturer data applied

  • Current CPHQ-CHA-ENG-014 Rev 03, dated 8 April 2026, page 5 supersedes the older 800-PSIG / 1,500-lbf configuration. Use the current 1,400-PSIG / 3,000-lbf configuration with a 15:1 reducer.
  • The 1750-RPM and 1450-RPM paths were traced independently from the current chart. Values are approximate to about ±0.1 US gal/h, not original numeric measurements. Mechanical minimum remains zero; each curve maximum ÷ 40 is the separate conservative sizing floor.
  • The shaded 1,400–1,700 PSIG extension is pending final engineering validation. No curve point or recommendation above 1,400 PSIG is included.
  • The supplied motor workbook dated 1 June 2026 supports the 3,000-lbf, 15:1 configuration. Its 1,700-PSIG row does not override the 1,400-PSIG performance-chart limit.

Current performance PDF · page 5 CPHQ-CHA-ENG-014 · Rev 03 · Effective 08/APRIL/2026 Source record

Motor configuration cross-check: supplied engineering motor workbook · 1 June 2026. No public workbook URL is asserted.

Current curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. Each motor curve was traced separately; the pending range above 1,400 PSIG is excluded.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 1.275 US gal/h (curve maximum ÷ 40).0 → 51; 500 → 49.5; 1,400 → 48.1
1450RPM Motor w/ 15:1 ReducerSizing floor: 1.05 US gal/h (curve maximum ÷ 40).0 → 42; 550 → 40.9; 1,400 → 39.5

Series ATP HP 1

Series ATP 3/8" HP Single Head - ModularSupplied source only
5,000 PSIG MAWP0 US gal/h minimum field2 published curves

Additional curve model

  • Current values visually agree with the supplied Rev 00 graph to its approximate 0.01 US gal/h digitization.
  • Retain supplied-document provenance; current public-website verification was not established.
  • 13.18:1 reducer and 1750/1450 RPM confirmed; do not extrapolate above 5000 PSIG.

Supplied ATP HP performance document · CPHQ-CHA-ENG-005 · Rev 00 · 23 April 2026 · page 1. A current public URL was not established.

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 13.18:1 Reducer0 → 2.77; 3,000 → 2.42; 5,000 → 2.33
1450RPM Motor w/ 13.18:1 Reducer0 → 2.33; 3,000 → 2; 5,000 → 1.93

Series SLA LeakLess 4

Series SLA LeakLess 3/8"Chart checked
13,500 PSIG MAWP0 US gal/h minimum field2 published curves

Additional curve model

  • All 30 knots across the four LeakLess models agree with official PDF vector geometry within 0.006 US gal/h.
  • Minimum 0 agrees with the product table. Recommended sizing turndown of 40:1 and API accuracy at 10–100% maximum flow with viscosity up to 10 cP are separate operating guidance.
  • 1750/1450 RPM and 15:1 ratio confirmed. Each curve uses maximum flow ÷ 40 as a conservative sizing floor, separate from mechanical minimum zero.

Performance PDF · page 1 CPHQ/CHA-MRK-050 · Rev 02 · Effective 01 Aug 2024 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.0795 US gal/h (curve maximum ÷ 40).0 → 3.18; 3,000 → 2.893; 12,000 → 2.352; 13,500 → 2.352
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.06585 US gal/h (curve maximum ÷ 40).0 → 2.634; 3,000 → 2.397; 12,000 → 1.95; 13,500 → 1.95
Series SLA LeakLess 1/2"Chart checked
7,600 PSIG MAWP0 US gal/h minimum field2 published curves

Additional curve model

  • All 30 knots across the four LeakLess models agree with official PDF vector geometry within 0.006 US gal/h.
  • Minimum 0 agrees with the product table. Recommended sizing turndown of 40:1 and API accuracy at 10–100% maximum flow with viscosity up to 10 cP are separate operating guidance.
  • 1750/1450 RPM and 15:1 ratio confirmed. Each curve uses maximum flow ÷ 40 as a conservative sizing floor, separate from mechanical minimum zero.

Performance PDF · page 2 CPHQ/CHA-MRK-050 · Rev 02 · Effective 01 Aug 2024 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.1413 US gal/h (curve maximum ÷ 40).0 → 5.652; 2,000 → 5.076; 4,000 → 4.669; 7,600 → 4.06
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.117075 US gal/h (curve maximum ÷ 40).0 → 4.683; 2,000 → 4.205; 4,000 → 3.869; 7,600 → 3.364
Series SLA LeakLess 3/4"Chart checked
3,300 PSIG MAWP0 US gal/h minimum field2 published curves

Additional curve model

  • All 30 knots across the four LeakLess models agree with official PDF vector geometry within 0.006 US gal/h.
  • Minimum 0 agrees with the product table. Recommended sizing turndown of 40:1 and API accuracy at 10–100% maximum flow with viscosity up to 10 cP are separate operating guidance.
  • 1750/1450 RPM and 15:1 ratio confirmed. Each curve uses maximum flow ÷ 40 as a conservative sizing floor, separate from mechanical minimum zero.

Performance PDF · page 3 CPHQ/CHA-MRK-050 · Rev 02 · Effective 01 Aug 2024 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.318 US gal/h (curve maximum ÷ 40).0 → 12.72; 1,000 → 12.18; 2,000 → 11.78; 3,300 → 11.47
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.263475 US gal/h (curve maximum ÷ 40).0 → 10.539; 1,000 → 10.092; 2,000 → 9.761; 3,300 → 9.5
Series SLA LeakLess 1"Chart checked
1,900 PSIG MAWP0 US gal/h minimum field2 published curves

Additional curve model

  • All 30 knots across the four LeakLess models agree with official PDF vector geometry within 0.006 US gal/h.
  • Minimum 0 agrees with the product table. Recommended sizing turndown of 40:1 and API accuracy at 10–100% maximum flow with viscosity up to 10 cP are separate operating guidance.
  • 1750/1450 RPM and 15:1 ratio confirmed. Each curve uses maximum flow ÷ 40 as a conservative sizing floor, separate from mechanical minimum zero.

Performance PDF · page 4 CPHQ/CHA-MRK-050 · Rev 02 · Effective 01 Aug 2024 Source record

Curve labels and digitized points

Pressure in PSIG → approximate flow in US gal/h. A point beyond MAWP does not extend the permitted operating range.

CurvePressure → flow
1750RPM Motor w/ 15:1 ReducerSizing floor: 0.56525 US gal/h (curve maximum ÷ 40).0 → 22.61; 1,000 → 21.519; 1,900 → 21.317
1450RPM Motor w/ 15:1 ReducerSizing floor: 0.46835 US gal/h (curve maximum ÷ 40).0 → 18.734; 1,000 → 17.83; 1,900 → 17.662

Series MD 6

Series MDAExcluded · table only
1,200 PSIG MAWP3 US gal/h minimum field0 published curves180 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and metallic-head pressure rating match.
  • The table is for quick reference. The official page directs users to CheckPoint for performance curves. Pressure-dependent capacity remains unverified.

Product page Source record

Series MDBExcluded · table only
2,500 PSIG MAWP10.8 US gal/h minimum field0 published curves180 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and metallic-head pressure rating match.
  • The table is for quick reference. The official page directs users to CheckPoint for performance curves. Pressure-dependent capacity remains unverified.

Product page Source record

Series MDCExcluded · table only
1,000 PSIG MAWP2.4 US gal/h minimum field0 published curves480 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and metallic-head pressure rating match.
  • The table is for quick reference. The official page directs users to CheckPoint for performance curves. Pressure-dependent capacity remains unverified.

Product page Source record

Series MDDExcluded · table only
2,500 PSIG MAWP80.4 US gal/h minimum field0 published curves804 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and metallic-head pressure rating match.
  • The table is for quick reference. The official page directs users to CheckPoint for performance curves. Pressure-dependent capacity remains unverified.

Product page Source record

Series MDEExcluded · table only
1,000 PSIG MAWP72 US gal/h minimum field0 published curves1,200 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and metallic-head pressure rating match.
  • The table is for quick reference. The official page directs users to CheckPoint for performance curves. Pressure-dependent capacity remains unverified.

Product page Source record

Series MDFExcluded · table only
1,100 PSIG MAWP21 US gal/h minimum field0 published curves2,190 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and metallic-head pressure rating match.
  • The table is for quick reference. The official page directs users to CheckPoint for performance curves. Pressure-dependent capacity remains unverified.

Product page Source record

Series MDZ 6

Series MDZ-001Excluded · table only
1,500 PSIG MAWP8.57 US gal/h minimum field0 published curves60 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and 1500 PSIG metallic-head MAWP match.
  • Archived reference: flow is expressly rated at 1000 PSIG and 1750 RPM (60 Hz), with an elastomeric diaphragm. This model is excluded from every selector. The retained metallic-head rating is 1500 PSIG; constant capacity above the tested pressure is not verified.
  • The archived manufacturer data requires at least 50 PSIG backpressure.

Product page Source record

Series MDZ-005Excluded · table only
1,500 PSIG MAWP1.72 US gal/h minimum field0 published curves12.04 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and 1500 PSIG metallic-head MAWP match.
  • Archived reference: flow is expressly rated at 1000 PSIG and 1750 RPM (60 Hz), with an elastomeric diaphragm. This model is excluded from every selector. The retained metallic-head rating is 1500 PSIG; constant capacity above the tested pressure is not verified.
  • The archived manufacturer data requires at least 50 PSIG backpressure.

Product page Source record

Series MDZ-010Excluded · table only
1,500 PSIG MAWP0.84 US gal/h minimum field0 published curves5.87 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and 1500 PSIG metallic-head MAWP match.
  • Archived reference: flow is expressly rated at 1000 PSIG and 1750 RPM (60 Hz), with an elastomeric diaphragm. This model is excluded from every selector. The retained metallic-head rating is 1500 PSIG; constant capacity above the tested pressure is not verified.
  • The archived manufacturer data requires at least 50 PSIG backpressure.

Product page Source record

Series MDZ-025Excluded · table only
1,500 PSIG MAWP0.31 US gal/h minimum field0 published curves2.17 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and 1500 PSIG metallic-head MAWP match.
  • Archived reference: flow is expressly rated at 1000 PSIG and 1750 RPM (60 Hz), with an elastomeric diaphragm. This model is excluded from every selector. The retained metallic-head rating is 1500 PSIG; constant capacity above the tested pressure is not verified.
  • The archived manufacturer data requires at least 50 PSIG backpressure.

Product page Source record

Series MDZ-050Excluded · table only
1,500 PSIG MAWP0.13 US gal/h minimum field0 published curves0.94 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and 1500 PSIG metallic-head MAWP match.
  • Archived reference: flow is expressly rated at 1000 PSIG and 1750 RPM (60 Hz), with an elastomeric diaphragm. This model is excluded from every selector. The retained metallic-head rating is 1500 PSIG; constant capacity above the tested pressure is not verified.
  • The archived manufacturer data requires at least 50 PSIG backpressure.

Product page Source record

Series MDZ-100Excluded · table only
1,500 PSIG MAWP0.05 US gal/h minimum field0 published curves0.32 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The published model minimum and maximum flows and 1500 PSIG metallic-head MAWP match.
  • Archived reference: flow is expressly rated at 1000 PSIG and 1750 RPM (60 Hz), with an elastomeric diaphragm. This model is excluded from every selector. The retained metallic-head rating is 1500 PSIG; constant capacity above the tested pressure is not verified.
  • The archived manufacturer data requires at least 50 PSIG backpressure.

Product page Source record

Series S 2

Series S1X072PCTA10Excluded · table only
250 PSIG MAWP0 US gal/h minimum field0 published curves0.71 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The model table specifies 0.71 US gal/h maximum and 250 PSIG; both match.
  • The page introduction states 1.25 US gal/h, conflicting with the model table. Retain the model-specific 0.71 rating.
  • Minimum nonzero operating flow is not specified. Existing zero means control off, not a verified minimum continuous rate.

Product page Source record

Series S1X072SSTA10Excluded · table only
250 PSIG MAWP0 US gal/h minimum field0 published curves0.71 US gal/h table maximum

Archived backend reference · excluded from every selector

  • The model table specifies 0.71 US gal/h maximum and 250 PSIG; both match.
  • The page introduction states 1.25 US gal/h, conflicting with the model table. Retain the model-specific 0.71 rating.
  • Minimum nonzero operating flow is not specified. Existing zero means control off, not a verified minimum continuous rate.

Product page Source record

Source register · direct links, revisions and SHA-256 records

Official sources were retrieved on 8 October 2026. Effective dates are reproduced as printed; ambiguous numeric date formats are not reinterpreted. Hashes identify the bytes reviewed, not a guarantee that a remote file will remain unchanged.

  • Series-1250-18-1.pdf

    DOC ID: CPHQ/CHA-MRK-088 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 c648ce57e6819c39adba05cb171dd00260fb68efdb80aa39d547686bba9e2c6d
  • series-1250-pneumatic-pump

    Current product page; retrieved 8 October 2026

    SHA-256 2732f926f7a7c5eddf26c53da8118eba9c9dcf08fbc2a323aff4e6fa0ff36221
  • DOC1250-High-Pressure-.125FCP1-USGH-Rev23-Web-2-1.pdf

    DOC ID: CPHQ/CHA-MRK-016B REV. 25 EFF. DATE: 01 APR 2025

    SHA-256 3875eefa5f8c0abacf3f2323238fac8ed909e2129f6b93c55e682ffe12ef74bd
  • DOC1250-.125FCP1-USGH-REV22-1-1-1.pdf

    DOC ID: CPHQ/CHA-MRK-016A REV. 24 EFF. DATE: 01 APR 2025

    SHA-256 013901a4ea24b440a2fd21144f28651f04f8a227d486836b6a4776310dbafab9
  • Series-1250-316-1.pdf

    DOC ID: CPHQ/CHA-MRK-086 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 e25ed28fcf2235d9f84ff2fd31aebe611915057c05e3d6441b14c300a36b42de
  • DOC1250.1875FCP1-REV22-1.pdf

    DOC ID: CPHQ/CHA-MRK-017 REV. 22 EFF. DATE: 07 JUL 2025

    SHA-256 befb0510b973584c8fb29341b50cc71ba598525636928f206170c5cb01dea03d
  • Series-1250-14.pdf

    DOC ID: CPHQ/CHA-MRK-089 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 686e2b02dac8203709c9b65af1ef7b859cae79eddecc11eb1f4065795be3cf22
  • DOC1250-High-Pressure-.25FCP1-USGH-REV20-2-1.pdf

    DOC ID: CPHQ/CHA-MRK-018B REV. 22 EFF. DATE: 01 APR 2025

    SHA-256 7512cf9d7fcfaa009e9c8cbb80a37f6ead8233c4e66aa8661883fc4d58bad9ad
  • DOC1250-.25FCP1-USGH-REV20-1-2-1.pdf

    DOC ID: CPHQ/CHA-MRK-018A REV. 23 EFF. DATE: 01 APR 2025

    SHA-256 d545b00ad29ef2e1d78e7e5c7d5dbcfc5f21d4781d2d5f219a1960641804b267
  • Series-1250-38-1.pdf

    DOC ID: CPHQ/CHA-MRK-087 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 52c1e17db9fa2f1579bccbf6a725f26bf722c5dfc9266e16a154424c11352557
  • DOC1250.375FCP1-USGH-REV19-1-1-1.pdf

    DOC ID: CPHQ/CHA-MRK-019 REV. 21 EFF. DATE: 01 APR 2025

    SHA-256 b0323793fd07180a55553ae1ecc96a9952cef4a272aee562506359e9fd3e35b9
  • series-1250-12-doc-ID-.pdf

    DOC ID: CPHQ/CHA-MRK-090 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 fc1e4fbdc51ff1dc6dcd469b2354dcae738f4125037b403101c0f86fc4c0823e
  • DOC1250.5-FC1-USGH-REV21-1-1-1.pdf

    DOC ID: CPHQ/CHA-MRK-021 REV. 23 EFF. DATE: 01 APR 2025

    SHA-256 92abd8b27e735ee8e3df0b617f456ad65183adde8858010355da98b726802160
  • 1500-38.pdf

    DOC ID: CPHQ/CHA-MRK-081 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 72962d5d4603626c3e5b70d2e55cd8efbbe75981cc3a8031bd496552f0261abe
  • series-1500-pneumatic-pump

    Current product page; retrieved 8 October 2026

    SHA-256 d83079d7eab9016edd9f6813e0bd096925e8aec63fb1cb6ca69eb6c0f49d1cff
  • DOC1500-High-Pressure-.375FC1-USGH-REV13-1.pdf

    DOC ID: CP/CHA-ENG-022B REV. 13 EFF. DATE: 07/11/2022

    SHA-256 e905c2cfd4d49bff6e6d41bb0ea334e37ba27ff6b1d1a56ad778d94a7f5f2b58
  • Series-1500-12-1.pdf

    DOC ID: CPHQ/CHA-MRK-084 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 1cf6328c693a377eddb2aed6286635464e53231ad8a580b6f0fc169356a07978
  • DOC1500.5FCP1-USGH-REV14-1.pdf

    DOC ID: CP/CHA-ENG-023 REV. 14 EFF. DATE: 07/11/2022

    SHA-256 f6096b491211a2cd9d1628b77ccc97b3ce0a49aa3dbdbdcad9df678bb940647e
  • Series-1500-34-1.pdf

    DOC ID: CPHQ/CHA-MRK-082 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 c7282b87e08addf2ae0f7ff7374a8e671aee7f7f396060e58736129f98a3c1ea
  • DOC1500.75FCP1-USGH-REV13-1.pdf

    DOC ID: CP/CHA-ENG-024 REV. 13 EFF. DATE: 07/11/2022

    SHA-256 3d15cb1ab4a8fca7eecc0e71fbfe471675c6ddaa9294359762ec93b3d02bed27
  • Series-1500-1.pdf

    DOC ID: CPHQ/CHA-MRK-085 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 cb2476cc2c78a313ddb7b850fd49f9f7fcf8a6e3058ae041d05dd0d8336bfff9
  • DOC1500-1-FCP1-USGH-REV13-1.pdf

    DOC ID: CP/CHA-ENG-025 REV. 13 EFF. DATE: 07/11/2022

    SHA-256 4346a51b2d784b4ea807a83e542ddb98b23c33b57da116dc26a36597b6496560
  • Series-1500-1-12-1.pdf

    DOC ID: CPHQ/CHA-MRK-083 REV. 00 EFF. DATE: 27 OCT 2025

    SHA-256 88ba7032e766b82ad74c60079b5595ddea229a7f4c6645da8f669989c495c8f3
  • DOC1500-1.5FCP1-USGH-REV12-1.pdf

    DOC ID: CP/CHA-ENG-026 REV. 12 EFF. DATE: 07/11/2022

    SHA-256 5e20f28dff68fb458a209a1f081b06362b035af8ef086419f45979cd63c1edd1
  • DOC5408-.5FC1-REV09-1.pdf

    Rev CP/CHA-ENG-027 REV. 09 EFF. DATE: 07/12/2022 Page 1 of 1

    SHA-256 5369e0d3bd789958c9b5214cfdcb4ea04f19e98ab0c325356c3c55eba54b60d2
  • series-5400-pneumatic-pump

    Current product page; retrieved 8 October 2026

    SHA-256 2280b2b370669dfa588e5a994bb72ddb98ae2c29e2bcd208571ae047a8caba26
  • DOC5412-.75-FC1-REV10-1.pdf

    Rev CP/CHA-ENG-028 REV. 10 EFF. DATE: 07/12/2022 Page 1 of 1

    SHA-256 d97da39d57083e4be1b01670fcf078d5f95b2289e5671cff8ce31621ad101d73
  • DOC5416-1-FC1-REV10-1.pdf

    Rev CP/CHA-ENG-029 REV. 10 EFF. DATE: 07/12/2022 Page 1 of 1

    SHA-256 f3cd863d0bb33b46d425a767e4bac52bde884982ecae912f211caffbf3f37652
  • DOC5428-1.75-FC-REV10-1.pdf

    Rev CP/CHA-ENG-030 REV. 10 EFF. DATE: 07/12/2022 Page 1 of 1

    SHA-256 d9725d7b199e4cc1bd09c8aa34f669d724d11a78831eb5ce33841dbf12e15ee2
  • DOC5440-2.5-FC1-REV11-1.pdf

    Rev CP/CHA-ENG-031 REV. 11 EFF. DATE: 07/12/2022 Page 1 of 1

    SHA-256 9580a7ea81ed3441ac301bb3ebb0e7211f4af53d3568f9d96b456deda5466d9c
  • DOC6200-FCP1-REV08-1.pdf

    Rev CP/CHA-ENG-032 REV. 08 EFF. DATE: 07/13/2022 Page 1 of 1

    SHA-256 6a840ddb03e7ec335d00d1917f2eabd153659f0c62b113c8113063bef36199b7
  • series-6200-pneumatic-pump

    Current product page; retrieved 8 October 2026

    SHA-256 3dfc6c96e805d25103393738468e4a82bb9f7ffd012b7a8535b0d243b2f08776
  • DOC8408-.5-FC1-REV13-1.pdf

    Rev CP/CHA-ENG-033 REV. 13 EFF. DATE: 07/14/2022

    SHA-256 76c655751715af60c86c5b9aa8d7ea9b72e1835dc3f12b8577293d988adf4acb
  • series-8400-pneumatic-pump

    Current product page; retrieved 8 October 2026

    SHA-256 df247e5008eb0c8299d3ff0a974310d25d718f0450d72ed5a48bc48fe532f013
  • DOC8412FC1-.75-REV14-1.pdf

    Rev CP/CHA-ENG-034 REV. 14 EFF. DATE: 07/14/2022

    SHA-256 cb92dadb7633c5d4376681cf5df152a394a72083d8930b2d7928f70d2f647628
  • DOC8416-.5-FC1-REV13-1.pdf

    Rev CP/CHA-ENG-035 REV. 13 EFF. DATE: 07/14/2022

    SHA-256 71905f35c7097935727024b12d5eae437090d6a4316fab55a86f55263469cab5
  • DOC8428FC1-REV09-1.pdf

    Rev CP/CHA-ENG-036 REV. 09 EFF. DATE: 07/14/2022

    SHA-256 411b1d4a631f11219c7e32d0ed79dde2faeb5104f49d81acb10bbfaf73a9faaf
  • DOC8440-2.5-FC1-REV10-1.pdf

    Rev CP/CHA-ENG-037 REV. 10 EFF. DATE: 07/14/2022

    SHA-256 c2b371727c66f8258e5524a6ba7bbb3e3e93aba883a6394bcb5542371128ea59
  • DOCGX15-FCP1-.25-REV09-1.pdf

    Rev CP/CHA-ENG-038 REV. 09 EFF. DATE: 07/14/2022

    SHA-256 a40082cd33910e6bab80eaadeac2822f0424c607238f000e58f5b82d93bbbba4
  • series-gx15-economical-pneumatic-plunger-pump

    Current product page; retrieved 8 October 2026

    SHA-256 277cd28253e9fec0dd58597daf919b5211c50a73a365e9e34e3124933a146624
  • DOCFXA-1250-1500-VFD-Controlled-All-Curves-1-1.pdf

    CP/CHA-ENG-007 · Rev 00 · Effective 07/05/2022

    SHA-256 430f8d6be9d3a9c47506a750c907ca16b84a98e9217a4d9e9176b043633aef80
  • series-fxa-electric-pump

    Current product page; retrieved 8 October 2026

    SHA-256 a91479a0ece18e3bbb1b9b4355451a7be6ebca06673347b5dd6b9590bafb69f8
  • DOC-FXS-FLOW-CURVES-REV00-certified.pdf

    DOC-FXS-FLOW-CURVES · Rev 00

    SHA-256 ba4288b18e2ed3f5cfedb3f3db4df71477c37e11dbd0e48dae4504edad7025f4
  • series-fxs-solar-pump

    Current product page; retrieved 8 October 2026

    SHA-256 e44f9ac5547c0ecae30aaad4ab25c73cf80b7a21afba6ee494106f1306de6104
  • series-sla-electric-pump

    Current product page; retrieved 8 October 2026

    SHA-256 dd9cc72047a34b3fc70f93c9ae49eac23921a24bab8e09f924b2bfd080174e7a
  • Series-SLA-Performance-Data-Rev03-signed.pdf

    CPHQ-CHA-ENG-014 · Rev 03 · Effective 08/APRIL/2026

    SHA-256 a39b55d2918b2dbc806299c3fee86192f3c91f5b2dcc34efbec4674c00723cf9
  • Series-SLA-Performance-Data-Rev02-1.pdf

    Historical source: CP/CHA-ENG-014 · Rev 02 · Effective 07/08/2022. Superseded by Rev 03 for the current SLA 1-1/2-inch configuration.

    SHA-256 d4795694550b47f44bf318a0626c9cb48b2480ae1de37fbecd2e11cbe07411c5
  • ATP-Fixed-AC-signed.pdf

    CPHQ-CHA-MRK-051 · Rev 01 · Effective 01 May 2025

    SHA-256 6302de117822c8cd15e6c9c3e4302f869d144fa523c8e3ce39904d081606bf23
  • Series-ATP-Modular-Motor-Data.pdf

    CPHQ/CHA-MRK-050 · Rev 01 · Effective 01 May 2025

    SHA-256 6fd89588715cf1984171a5edd4ab55160e0eefcd272a0afb68c0578ca10ec1f3
  • ATP-Fixed-DC-signed.pdf

    CPHQ-CHA-MRK-052 · Rev 01 · Effective 01 May 2025

    SHA-256 e632803fc9f0e83dc4c2324e34a712cc3b50bf84c076e88e45b6839dafae95f4
  • Series-SLA-LeakLess-Performance-Data-Rev02-copy-1.pdf

    CPHQ/CHA-MRK-050 · Rev 02 · Effective 01 Aug 2024

    SHA-256 e63aebb87d0438190d9e1d32288532e5cb955250d4b3fd4b2932088f7eab4711
  • series-md-electric-pump

    Current product page; retrieved 8 October 2026

    SHA-256 d6f63f5e16c5e9e1de0d30889a27d1542f4291cfe5d5b96dfe81b03c547ed352
  • series-mdz-electric-pump

    Current product page; retrieved 8 October 2026

    SHA-256 518f2f698e543051425113092256a480d1eeb23601a49f1dedef8e2ee78264ec
  • series-s-solenoid-pump

    Current product page; retrieved 8 October 2026

    SHA-256 026c82e0d6ebdc745733807ead4449e32fe4b128520d4cd17654ef8ffc8bcc5e
  • Series-FXA-with-VFD-Motor-Power-Charts-Rev01-1.pdf

    CP/CHA-ENG-009 · Rev 01 · Effective 04/06/2023

    SHA-256 d37aa97f191c353574612da86f9934d0818de2697f788f2df4ca4ff476a7016c
  • Series-SLA-with-Plunger-Head-Motor-Power-Charts-Rev03-copy-1.pdf

    CPHQ/CHA-MRK-040 · Rev 03 · Effective 08 Jul 2025

    SHA-256 710375a32113efc80d6026dce30237be1f37a6da07632da78c76c81fdf52e6a6
  • CP_CHA-ENG-042-Series-LeakLess-Motor-Power-Chart-1.pdf

    CP/CHA-ENG-042 · Rev 01 · Effective 04/10/2023